Ganglionated plexi ablation with pulmonary vein isolation after testing dormant pulmonary vein conduction and excluding non-pulmonary triggers in patients with paroxysmal atrial fibrillation
Published 2018-11-20
Keywords
- atrial fibrillation,
- dormant conduction,
- ganglionated plexi,
- high frequency stimulation,
- radiofrequency ablation
How to Cite
Copyright (c) 2018 Krivosheev Yu. S., Bashta D. I., Simonyan A. A., Krasilnikova S. Yu., Vilenskiy L. I., Myznikova T. A., Mishodzheva Z. A., Kolesnikov V. N.

This work is licensed under a Creative Commons Attribution 4.0 International License.
Abstract
Background. Pulmonary vein isolation (PVI) is the gold standard of interventional atrial fibrillation (AF) treatment, however, it doesn't provide a stable clinical effect and durable PVI in the long-term follow-up due to reconnections within the ablation line. To increase the efficacy of surgery, modulation of the autonomic nervous system can be combined with pulmonary vein isolation.
Aim. The study was focused on the evaluation of efficacy of ganglionated plexi (GP) ablation combined with PVI, and intraoperative drug testing of dormant pulmonary vein conduction and exclusion of non-pulmonary vein triggers in patients with paroxysmal atrial fibrillation.
Methods. There hundred sixty-seven patients with paroxysmal AF scheduled for catheter ablation were initially screened. PVI was performed in all patients. After testing with adenosine triphosphate and isoprenaline for dormant conduction following PVI and exclusion of non-pulmonary vein triggers, 194 patients with a positive response to high-frequency stimulation in the main GP sites of the left atrium were randomized in two groups: PVI (group I, n = 97), PVI with anatomical GP ablation (group II, n = 97). To perform continuous ECG monitoring, 53 patients received implantable cardiac monitors. The primary endpoint of the study was the freedom from any atrial tachyarrhythmias after 12 months of follow- up as recorded by 24-hour Holter monitoring. The secondary endpoints included AF burden based on implantable cardiac monitors data and predictors of AF recurrences. The patients were followed 3, 6, 9, 12 months after the ablation procedure.
Results. The mean follow-up was 12.5±2.2 months. By the end of the follow-up, 79 (81.4%) patients in the PVI with GP ablation group and 58 (59.8%) patients in the PVI only group were free from any atrial tachyarrhythmia (р=0.0012; log-rank test, HR 0.41, 95% CI [0.23–0.72], р=0.002; Cox regression). Implantable cardiac monitors data revealed that AF burden was significantly lower in the PVI with GP group as compared with the PVI only group (14.8±1.7% and 5.4±0.7%, р<0.001). According to the multivariable regression analysis, the independent predictors of AF recurrences were AF duration and presence of diabetes mellitus, while GP ablation reduced the risk of AF recurrence by 61%.
Conclusion. Ganglionated plexi ablation combined with pulmonary vein isolation confirmed by testing dormant conduction and excluding non-pulmonary triggers provides higher efficacy in maintaining the sinus rhythm as compared with PVI only in patients with paroxysmal atrial fibrillation.
Received 17 July 2018. Revised 7 August 2018. Accepted 10 August 2018.
Funding: The study did not have sponsorship.
Conflict of interest: Authors declare no conflict of interest.
Author contributions
Conception and study design: Yu.S. Krivosheev, L.I. Vilenskiy, V.N. Kolesnikov
Data collection and analysis: Yu.S Krivosheev, D.I. Bashta, A.A. Simonyan
Drafting the article: Yu.S. Krivosheev, A.A. Simonyan, D.I. Bashta, S.Yu. Krasilnikova
Critical revision of the article: V.N. Kolesnikov
Final approval of the version to be published: Yu.S. Krivosheev, D.I. Bashta, A.A. Simonyan, S.Yu. Krasilnikova, L.I. Vilenskiy, T.A. Myznikova, Z.A. Mishodzheva, V.N. Kolesnikov
References
- Haissaguerre M., Hocini M., Sanders P., Sacher F., Rotter M., Takahashi Y., Rostok T., Hsu L.F., Bordachar P., Reuter S., Roudaut R., Clementy J., Jais P. Catheter ablation of long-lasting persistent atrial fibrillation: clinical outcome and mechanisms of subsequent arrhythmias. J Cardiovasc Electrophysiol. 2005;16(11):1138-1147. PMID: 16302893. https://doi.org/10.1111/j.1540-8167.2005.00308.x
- Calkins H., Hindricks G., Cappato R., Kim Y-H, Saad E., Aguinaga L., Akar J.G., Badhwar V., Brugada J., Camm J., Chen P-S., Chen S-A., Chung M.K., Nielsen J.C., Curtis A.B., Davies D.W., Day J.D., d’Avila A., de Groot N.M.S., Di Biase L., Duytschaever M., Edgerton J.R., Ellenbogen K.A., Ellinor P.T., Ernst S., Fenelon G., Gerstenfeld E.P., Haines D.E., Haissaguerre M., Helm R.H., Hylek E., Jackman W.M., Jalife J., Kalman J.M., Kautzner J., Kottkamp H., Kuck K-H., Kumagai K., Lee R., Lewalter T., Lindsay B.D., Macle L., MD, Mansour M., Marchlinski F.E., Michaud G.F., Nakagawa H., Natale A., Nattel S., Okumura K., Packer D., Pokushalov E., Reynolds M.R., Sanders P., Scanavacca M., Schilling R., Tondo C., Tsao H-M., Verma A., Wilber D.J., Yamane T. 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm. 2017;14(10):e275-e444. PMID: 28506916, PMCID: PMC6019327. https://doi.org/10.1016/j.hrthm.2017.05.012
- Ouyang F., Tilz R., Chun J., Schmidt B., Wissner E., Zerm T., Neven K., Kokturk B., Konstantinidou M., Metzner A., Fuernkranz A., Kuck K.H. Long-term results of catheter ablation in paroxysmal atrial fibrillation: Lessons from a 5-year follow-up. Circulation. 2010;122(23):2368-77. PMID: 21098450. https://doi.org/10.1161/110.946806
- Miyazaki S., Kuwahara T., Kobori A., Takahashi Y., Takei A., Sato A., Isobe M., Takahashi A. Impact of adenosine-provoked acute dormant pulmonary vein conduction on recurrence of atrial fibrillation. J Cardiovasc Electrophysiol. 2012;23(2):256-60. PMID: 22034876. https://doi.org/10.1111/j.1540-8167.2011.02195.x
- Cheng H., Dai Y.Y., Jiang R.H., Liu Q., Sun Y.X.6 Lin J.W., Zhang Z.W., Chen S.Q., Zhu J., Sheng X., Jiang C.Y. Non-pulmonary vein foci induced before and after pulmonary vein isolation in patients undergoing ablation therapy for paroxysmal atrial fibrillation: incidence and clinical outcome. J Zhejiang Univ-Sci B (Biomed & Biotechnol). 2014;15(10):915-922. PMCID: PMC4201320, PMID: 25294381. https://doi.org/10.1631/jzus.B1400146
- Po S.S., Scherlag B.J., Yamanashi W.S., Edwards J., Zhou J., Wu R., Geng N., Lazzara R., Jackman W.M. Experimental model for paroxysmal atrial fibrillation arising at the pulmonary vein-atrial junctions. Heart Rhythm. 2006;3(2):201-8. PMID: 16443537. https://doi.org/10.1016/j.hrthm.2005.11.008
- Шабанов В.В., Романов А.Б., Туров А.Н., Елесин Д.А, Стенин И.Г., Якубов А.А., Лосик Д.В., Покушалов Е.А., Артеменко С.Н., Баранова В.В. Пятилетний опыт использования радиочастотной аблации ганглионарных сплетений левого предсердия у пациентов с пароксизмальной формой фибрилляции предсердий. Вестник аритмологии. 2010;(61):5-10. Режим доступа: http://www.vestar.ru/article.jsp?id=10792 [Shabanov V.V., Romanov A.B., Turov A.N., Elesin D.A., Stenin I.G., Yakubov A.A., Losik D.V., Pokushalov E.A., Artemenko S.N., Baranova V.V. Five year experience of radiofrequency ablation of ganglionar plexuses in the left atrium in patients with paroxysmal atrial fibrillation. Vestnik aritmologii = Journal of arrhythmology. 2010;(61):5-10. (In Russ.) Available from http://www.vestar.ru/article.jsp?id=10792]
- Pokushalov E., Romanov A., Artyomenko S., Shirokova N., Turov A., Karaskov A., Katritsis D.G., Po S.S. Ganglionated plexi ablation directed by high-frequency stimulation and complex fractionated atrial electrograms for paroxysmal atrial fibrillation. Pacing Clin Electrophysiol. 2012;35(7):776-84. PMID: 22486215. https://doi.org/10.1111/j.1540-8159.2012.03392.x
- Lemery R., Birnie D., Tang A.S.L., Green M., Gollob M. Feasibility study of endocardial mapping of ganglionated plexuses during catheter ablation of atrial fibrillation. Heart Rhythm. 2006;3(4):387-96. PMID: 16567283. https://doi.org/10.1016/j.hrthm.2006.01.009
- Pokushalov E., Romanov A., Shugayev P., Artyomenko S., Shirokova N., Turov A., Katritsis D.G. Selective ganglionated plexi ablation for paroxysmal atrial fibrillation. Heart Rhythm. 2009;6(9):1257-64. PMID: 19656736. https://doi.org/10.1016/j.hrthm.2009.05.018
- Kurotobi T., Shimada Y., Kino N., Ito K.,Tonomura D., Yano K., Tanaka C., Yoshida M., Tsushida T., Fukumoto H. Features of intrinsic ganglionated plexi in both atria after extensive pulmonary isolation and their clinical significance after catheter ablation in patients with atrial fibrillation, Heart Rhythm. 2015;12(3):470-476. PMID: 25433142. http://dx.doi.org/10.1016/j.hrthm.2014.11.033
- Kirchhof P., Benussi S., Kotecha D., Ahlsson A., Atar D., Casadei B., Castella M., Diener H-C., Heidbuchel H., Hendriks J., Hindricks G., Manolis A.S., Oldgren J., Popescu B.A., Schotten U., Putte B.V., Vardas P. 2016 ESC Guidelines for the management of atrial fibrillation developed in collaboration with EACTS. The Task Force for the management of atrial fibrillation of the European Society of Cardiology (ESC). Developed with the special contribution of the European Heart Rhythm Association (EHRA) of the ESC. Endorsed by the European Stroke Organisation (ESO). Europ Heart J. 2016;37(38):2893-2962. PMID: 27567408. https://doi.org/10.1093/eurheartj/ehw210
- Jiang R.H., Jiang C.Y., Sheng X., Zhang Z.W., Sun Y.X., Liu Q., Fu G.S., Po S.S. Marked suppression of pulmonary vein firing after circumferential pulmonary vein isolation in patients with paroxysmal atrial fibrillation: is pulmonary vein firing an epiphenomenon? J Cardiovasc Electrophysiol. 2014;25(2):111-8. PMID: 24118531. http://dx.doi.org/10.1016/j.hrthm.2014.03.015
- Елесин Д.А., Романов А.Б., Туров А.Н., Шабанов В.В., Стенин И.Г., Якубов А.А., Лосик Д.В., Артеменко С.Н., Панфилов С.В., Покушалов Е.А. Радиочастотная аблация пароксизмальной и длительно персистирующей формы фибрилляции предсердий: 1-летний период наблюдения с помощью непрерывного подкожного мониторирования. Вестник аритмологии. 2011;(63):5-11. Режим доступа: http://www.vestar.ru/article.jsp?id=11232 [Elesin D.A., Romanov A.B., Turov A.N., Shabanov V.V., Stenin I.G., Yakubov A.A., Losik D.V., Artemenko S.N., Panfilov S.V., Pokushalov E.A. Radiofrequency ablation of paroxysmal and prolonged persistent atrial fibrillation: one-tear follow-up with the use of continuous subcutaneous monitoring. Vestnik aritmologii = Journal of arrhythmology. 2011;(63):5-11. (In Russ.) Available from http://www.vestar.ru/article.jsp?id=11232]
- Байрамова С.А., Романов А.Б., Миттал С., Мусат Д., Стейнберг Д., Е.А. Покушалов Имплантируемый аппарат длительного мониторирования ЭКГ для выявления фибрилляции предсердий после аблации кавотрикуспидального перешейка у пациентов с трепетанием предсердий. Патология кровообращения и кардиохирургия. 2015;19(3):100-109. http://dx.doi.org/10.21688/1681-3472-2015-3-100-109 [Bayramova S.A., Romanov A.B., Mittal S., Musat D., Steinberg J.S., Pokushalov Ye.A. Long-term ECG monitoring using an implantable loop recorder for the detection of atrial fibrillation after cavotricuspid isthmus ablation in patients with atrial flutter. Patologiya krovoobrashcheniya i kardiokhirurgiya = Circulation Pathology and Cardiac Surgery. 2015;19(3):100-109. (In Russ.) http://dx.doi.org/10.21688/1681-3472-2015-3-100-109]
- Pokushalov E., Romanov A., De Melis M., Artyomenko S., Baranova V., Losik D., Bairamova S., Karaskov A., Mittal S., Steinberg J.S. Progression of atrial fibrillation after a failed initial ablation procedure in patients with paroxysmal atrial fibrillation. A randomized comparison of drug therapy versus reablation. J Circ Arrhythm Electrophysiol. 2013;6(4):754-760. PMID: 23748210. http://dx.doi.org/10.1161/CIRCEP.113.000495
- Romanov A., Goscinska-Bis K., Bis J., Chernyavskiy A., Prokhorova D., Syrtseva Y., Shabanov V., Alsov S., Karaskov A., Deja M., Krejca M., Pokushalov E. Cardiac resynchronization therapy combined with coronary artery bypass grafting in ischaemic heart failure patients: long-term results of the RESCUE study. Eur J Cardiothoracic Surg. 2016;50(1):36-41. PMID: 26719401. http://dx.doi.org/10.1093/ejcts/ezv448
- Pappone C., Santinelli V., Manguso F., Vicedomini G., Gugliotta F., Augello G., Mazzone P., Tortoriello V., Landoni G., Zangrillo A., Lang C.,Tomita T., Mesas C., Mastella E., Alfieri O. Pulmonary vein denervation enhances long-term benefit after circumferential ablation for paroxysmal atrial fibrillation. Circulation. 2004;109(3):327-334. PMID: 14707026. http://dx.doi.org/10.1161/01.CIR.0000112641.16340.C7
- Покушалов Е.А., Туров А.Н., Романов А.Б., Широкова Н.В., Селина В.В., Панфилов С.В. Сравнительный анализ процедуры C.Pappone и анатомической аблации ганглионарных сплетений у пациентов с фибрилляцией предсердий. Вестник аритмологии. 2011;(64):16-22. Режим доступа: http://www.vestar.ru/article.jsp?id=11249 [Pokushalov E.A., Turov A.N., Romanov A.B., Shirokova N.V., Selina V.V., Panfilov S.V. Comparative analysis os procedure by Pappone and anatomic ablation of ganglionar plexuses in patients with atrial fibrillation. Vestnik aritmologii = Journal of arrhythmology. 2011;(64):16-22. (In Russ.) Available from http://www.vestar.ru/article.jsp?id=11249]
- Katritsis D.G., Giazitzoglou E., Zografos T., Pokushalov E., Po S.S., Camm A.J. Rapid pulmonary vein isolation combined with autonomic ganglia modification: a randomized study. Heart Rhythm. 2011;8(5):672-678. PMID: 21199686. http://dx.doi.org/10.1016/j.hrthm.2010.12.047
- Zhang Y., Wang Z., Zhang Y., Wang W., Wang J., Gao M., Hou Y. Efficacy of cardiac autonomic denervation for atrial fibrillation: a meta-analysis. J Cardiovasc Electrophysiol. 2012;23(6):592-600. PMID: 22429251. http://dx.doi.org/10.1111/j.1540-8167.2011.02270.x
- Hachiya H., Hirao K., Takahashi A., Nagata Y., Suzuki K., Maeda S., Sasaki T., Kawabata M., Isobe M., Iesaka Y. Clinical implications of reconnection between the left atrium and isolated pulmonary veins provoked by adenosine triphosphate after extensive encircling pulmonary vein isolation. J Cardiovasc Electrophysiol. 2007;18(4):392-8. PMID: 17286569. http://dx.doi.org/10.1111/j.1540-8167.2006.00753.x
- Romanov A., Minin S., Breault Ch., Pokushalov E. Visualisation and ablation of the autonomic nervous system corresponding to ganglionated plexi guided by D-SPECT 123I-mIBG imaging in patient with paroxysmal atrial fibrillation. Clin Res Cardiol. 2017;106(1):76-78. PMID: 27752762. http://dx.doi.org/10.1007/s00392-016-1045-2