Access to the left atrium during transseptal puncture for radiofrequency ablation in patients with atrial fibrillation (AF) and implanted atrial septal occluder can be challenging. This is particularly true when the occluder covers the entire septum and there is no ideal puncture site. This might lead to potential difficulties in arrhythmia treatment.
A 59-year-old patient with drug refractory AF, a dilated left atrium, and an implanted atrial septal occluder underwent double transseptal puncture through atrial septal occluder with subsequent pulmonary vein isolation using remote magnetic navigation. The effectiveness of the manipulation was confirmed by intraoperative stimulation from the Lasso catheter and by Holter monitoring data post-operation. It was revealed that the patient had sinus rhythm and no complications occurred. There were no shunts at the occluder level on transthoracic echocardiography, and there were no atrial tachyarrhythmias during the nine-month follow up period without antiarrhythmic drugs. The presented clinical case demonstrates the safety and efficacy of transseptal puncture through an implanted occluder in the interatrial septum to perform re-ablation using robotic magnetic navigation in a patient with AF.
Received 21 October 2020. Revised 20 November 2020. Accepted 25 November 2020.
Funding: The work is supported by a grant of the President of the Russian Federation No. МД-1997.2020.7.
Conflict of interest: Authors declare no conflict of interest.
Author contributions
Drafting the article: А.V. Ponomarenko, R.E. Zhizhov, V.V. Baranova, E.V. Fisher, A.B. Romanov
Literature review: А.V. Ponomarenko, R.E. Zhizhov, V.V. Baranova, E.V. Fisher
Illustrations: А.V. Ponomarenko, A.B. Romanov
Critical revision of the article: А.V. Ponomarenko, R.E. Zhizhov, V.V. Baranova, A.M. Chernyavskiy, A.B. Romanov
Surgical treatment: N.А. Yelemessov, I.S. Peregudov, V.V. Shabanov, A.B. Romanov
Final approval of the version to be published: А.V. Ponomarenko, N.А. Yelemessov, I.S. Peregudov, R.E. Zhizhov, V.V. Baranova, E.V. Fisher, V.V. Shabanov, A.M. Chernyavskiy, A.B. Romanov
References
- Fagundes R.L., Mantica M., De Luca L., Forleo G., Pappalardo A., Avella A., Fraticelli A., Dello Russo A., Casella M., Pelargonio G., Tondo C. Safety of single transseptal puncture for ablation of atrial fibrillation: Retrospective study from a large cohort of patients. J Cardiovasc Electrophysiol. 2007;18(12):1277-1281. PMID: 17883403. https://doi.org/10.1111/j.1540-8167.2007.00958.x
- Li X., Wissner E., Kamioka M., Makimoto H., Rausch P., Metzner A., Mathew S., Rillig A., Richard Tilz R., Fürnkranz A., Chen Q., Zhang Q., Liu Q., Zhou S., Kuck K.-H., Ouyang F. Safety and feasibility of transseptal puncture for atrial fibrillation ablation in patients with atrial septal defect closure devices. Heart Rhythm. 2014;11(2):330-335. PMID: 24239844. https://doi.org/10.1016/j.hrthm.2013.11.011
- Romanov A., Filippenko A., Elesin D., Losik D., Grishkov A., Shabanov V. Remote magnetic navigation ablation via the right jugular vein approach in patient with interruption of the inferior vena cava and incessant left atrial flutter. Pacing Clin Electrophysiol. 2021;44(2):385-388. PMID: 32969523. https://doi.org/10.1111/pace.14078
- Santangeli P., Di Biase L., Burkhardt J.D., Horton R., Sanchez J., Bailey S., Zagrodzky J.D., Lakkireddy D., Bai R., Mohanty P., Beheiry S., Hongo R., Natale A. Transseptal access and atrial fibrillation ablation guided by intracardiac echocardiography in patients with atrial septal closure devices. Heart Rhythm. 2011;8(11):1669-1675. PMID: 21703215. https://doi.org/10.1016/j.hrthm.2011.06.023
- Villablanca P.A., Lee J., Wang D.D., Frisoli T., So C.-Y, Kang G., O’Neill W.W., Eng M.H. Transseptal puncture through an Amplatzer Atrial Septal Occluder for edge-to-edge repair with MitraClip NTr system. Cardiovasc Revasc Med. 2020;21(11S):63-64. PMID: 32224042. https://doi.org/10.1016/j.carrev.2020.02.021
- Yao Y., Ding L., Chen W., Guo J., Bao J., Shi R., Huang W., Zhang S., Wong T. The training and learning process of transseptal puncture using a modified technique. Europace. 2013;15(12):1784-1790. PMID: 23946317. https://doi.org/10.1093/europace/eut078
- Virk S.A., Kumar S. Remote magnetic versus manual catheter navigation for atrial fibrillation ablation: A meta-analysis. Circ Arrhythm Electrophysiol. 2019;12(10):e007517. PMID: 31607150. https://doi.org/10.1161/CIRCEP.119.007517