Vol. 21 No. 3 (2017)
ACQUIRED HEART DISEASES

Quality of life after aortic valve replacement with biological prostheses in elderly patients

D. Demidov
Meshalkin National Medical Research Center, Ministry of Health of Russian Federation, Novosibirsk, Russian Federation
Bio
D. Astaspov
Meshalkin National Medical Research Center, Ministry of Health of Russian Federation, Novosibirsk, Russian Federation
A. Bogachev-Prokophiev
Meshalkin National Medical Research Center, Ministry of Health of Russian Federation, Novosibirsk, Russian Federation
S. Zheleznev
Meshalkin National Medical Research Center, Ministry of Health of Russian Federation, Novosibirsk, Russian Federation

Published 2017-11-22

Keywords

  • aortic valve disease,
  • aortic valve replacement,
  • biological prosthesis,
  • heart failure

How to Cite

Demidov, D., Astaspov, D., Bogachev-Prokophiev, A., & Zheleznev, S. (2017). Quality of life after aortic valve replacement with biological prostheses in elderly patients. Patologiya Krovoobrashcheniya I Kardiokhirurgiya, 21(3), 40–47. https://doi.org/10.21688/1681-3472-2017-3-40-47

Abstract

Aim. The paper aims to assess the quality of life of patients subjected to aortic valve replacement with a stented/stentless biological prosthesis.
Methods. The research was done at the Acquired Heart Disease Department of Meshalkin National Medical Research Center. The inclusion criteria were patient age older than 65 years and severe stenosis of the aortic valve. 114 patients were randomized 1:1 in two groups: group I patients received stentless biological prostheses, while group II patients — stented xenopericardial ones. All patients underwent aortic valve replacement under normothermic cardiopulmonary bypass. Mean follow-up was 3.9 [2.77; 4.55] years, mean age 71.5±4 (65–84) years, mean left ventricle ejection fraction 65.5 (40–86) % and mean preoperative Log.Euroscore 5.4±1.3 (1.4–12.4). The quality of life was assessed by using a standard questionnaire SF-36.
Results. Peak transprosthetic gradients at 1-year follow-up amounted to 16.22±4.34 and 24.66±4.74 mm Hg for group I and group II respectively. The 5-year survival rate was 90 [81; 99] % and 96 [90; 100] % for the two groups respectively and did not differ statistically (log rank test, p = 0.226). A statistically significant improvement of quality of life among patients in both groups was observed at 1-year follow-up, as compared to the preoperative values, however, marked intergroup differences in any of the parameters were not recorded.
Conclusion. The quality of life after aortic valve replacement with stented and stentless biological prostheses in elderly patients confirms clinical and functional efficiency of both methods, does not show sound advantages of any of them and improves both the physical component of health and subjective emotional level.

Received 25 July 2017. Revised 18 August 2017. Accepted 28 August 2017.

Funding: The study was carried out with the support of a grant of the President of the Russian Federation (МД–6967.2016.7) created to provide government assistance to the leading research centers in Russian Federation.

Conflict of interest: The authors declare no conflict of interest.

References

  1. Chocron S., Etievent J., Viel J., Dussaucy A., Clement F., Alwan K., Neidhardt M., Schipman N. Prospective study of quality of life before and after open heart operations. Ann Thorac Surg. 1996;61(1):153-7. PMID: 8561543. http://dx.doi.org/10.1016/0003-4975(95)00936-1
  2. Myken P., Larsson S., Berggren H., Caidahl K. Similar quality of life after heart valve replacement with mechanical or bioprosthetic valves. J Heart Valv Dis. 1995;4(4):339-45. PMID: 7582138
  3. Бабенко С.И., Муратов Р.М., Соболева Н.Н. Результаты протезирования аортального клапана каркасными и бескаркасными биопротезами серии «БиоЛаб». Клиническая физиология кровообращения. 2015;(1):30-5. Режим доступа: https://cfc-journal.com/catalog/detail.php?SECTION_ID=4013&ID=47368 [Babenko S.I., Muratov R.M., Soboleva N.N. Results of aortic valve replacement stented and stentless bioprostheses series BioLAB. Klinicheskaja fiziologija krovoobrashhenija = Clinical Physiology of Blood Circulaiton. 2015;(1):30-5. (In Russ.) Available at: https://cfc-journal.com/EN/catalog/detail.php?SECTION_ID=4013&ID=47368]
  4. Perchinsky M., Henderson C., Jamieson W., Anderson W. Jr, Lamy A., Lowe N., de Guzman S. Quality of life in patients with bioprostheses and mechanical prostheses. Evaluation of cohorts of patients aged 51 to 65 years at implantation. Circulation. 1998;98(Suppl II):81-6. discussion II86-7. PMID: 9852886
  5. Алекси-Месхишвили В.В., Дземешкевич С.Л., Стивенсон Л.У. Болезни аортального клапана. Функция. Диагностика. Лечение. М.: ГЭОТАР-Медиа, 2004. 328 с. [Aleksi-Meshishvili V.V., Dzemeshkevich S.L., Stivenson L.U. Bolezni aortalnogo klapana. Funktsiya. Diagnostika. Lechenie. Moscow, Geotar Media Publ.; 2004. 328 р.]
  6. Астапов Д.А., Демидов Д.П., Семенова Е.И. Протезирование аортального клапана бескаркасным биологическим протезом. Хирургия. Журнал им. Н.И. Пирогова. 2016;(5):4-12. http://dx.doi.org/10.17116/hirurgia201654-12 [Astapov D.A., Demidov D.P., Semenova E.I. Aortic valve replacement with stentless bioprosthesis. Khirurgiya. Zhurnal imeni N.I. Pirogova = Journal Surgery named after N.I. Pirogov. 2016(5):4-12. (In Russ.) http://dx.doi.org/10.17116/hirurgia201654-12]
  7. Астапов Д.А., Демидов Д.П., Семенова Е.И., Железнев С.И., Зорина И.Г., Сырцева Я.В. Первый опыт имплантации ксеноперикардиального протеза с каркасом переменной жесткости «ТиАра» в аортальную позицию. Патология кровообращения и кардиохирургия. 2013;17(2):73-5. [Astapov D.A., Demidov D.P., Semenova Ye.I., Zheleznev S.I., Zorina I.G., Syrtseva Ya.V. The first experience with the implantation of the prosthesis xenopericardial frame variable stiffness "Tiara" in the aortic position. Patologiya krovoobrashcheniya i kardiokhirurgiya = Circulation Pathology and Cardiac Surgery. 2013;17(2):73-75. (In Russ.) http://dx.doi.org/10.21688/1681-3472-2013-2-73-75]
  8. Nishimura R.A., Otto C.M., Bonow R.O., Carabello B.A., Erwin J.P., Fleisher L.A., Jneid H., Mack M.J., McLeod C.J., O’Gara P.T., Rigolin V.H., Sundt T.M., Thompson A. 017 AHA/ACC Focused Update of the 2014 AHA/ACC Guideline for the Management of Patients With Valvular Heart Disease: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines. Circulation. 2017;136(13). https://doi.org/10.1161/CIR.0000000000000503
  9. Караськов А.М., Журавлева И.Ю., Астапов Д.А., Стасев А.Н., Демидов Д.П., Одаренко Ю.Н., Барбараш Л.С. Клинико-гемодинамические результаты применения биопротезов «ЮниЛайн» в аортальной позиции. Кардиология и сердечно-сосудистая хирургия. 2014;(4):87-91. Режим доступа: https://www.mediasphera.ru/issues/kardiologiya-i-serdechno-sosudistaya-khirurgiya/2014/4/031996-63852014414 [Karas'kov A.M., Zhuravleva I.Ju., Astapov D.A. Stasev A.N., Demidov D.P., Odarenko Ju.N., Barbarash L.S Clinical and hemodynamic results of bioprostheses UniLine using in aortic position. Kardiologiya i serdechno-sosudistaya khirurgiya = Cardiology and Cardiovascular Surgery. 2014;(4):87-91. (In Russ.) Available at: https://www.mediasphera.ru/issues/kardiologiya-i-serdechno-sosudistaya-khirurgiya/2014/4/031996-63852014414]
  10. Астапов Д.А., Караськов А.М., Исаян М.В., Семенова Е.И., Демидов Д.П. Протезирование аортального клапана бескаркасным биопротезом «Кемерово-АБ-Нео»: непосредственные результаты. Патология кровообращения и кардиохирургия. 2012;16(1):23-6. http://dx.doi.org/10.21688/1681-3472-2012-1-23-26 [Astapov D.A., Karaskov A.M., Semenova Ye.I., Demidov D.P., Isayan M.V., Open A.B. Aortic valve replacement with stentless bioprosthesis "Kemerovo-AB-Neo". Patologiya krovoobrashcheniya i kardiokhirurgiya = Circulation Pathology and Cardiac Surgery. 2012;16(1):23-26. (In Russ.) http://dx.doi.org/10.21688/1681-3472-2012-1-23-26]
  11. Бокерия Л.А., Муратов Р.М., Бабенко С.И., Соболева Н.Н., Семенова Е.В. Новый бескаркасный ксеноперикардиальный протез «БиоЛАБ» в хирургии аортального клапана. Грудная и сердечно-сосудистая хирургия. 2015;57(1):25-31. Режим доступа: https://tcs-journal.com/catalog/detail.php?SECTION_ID=3936&ID=44878 [Bockeria L.A., Muratov R.M., Babenko S.I., Soboleva N.N., Semenova E.V. A new xenopericardial stentless bioprosthesis «BioLAB» in the surgery of aortic valve. Grudnaja i serdechno-sosudistaja hirurgija = Russian Journal of Thoracic and Cardiovascular Surgery. 2015;57(1):25-31. (In Russ.). Available at: https://tcs-journal.com/EN/catalog/detail.php?SECTION_ID=3936&ID=44878]
  12. Glauber M, Solinas M, Karimov J. Technique for implant of the stentless aortic valve Freedom Solo. Multimed Man Cardiothorac Surg. 2007;1:002618. PMID: 24415056. http://dx.doi.org/10.1510/mmcts.2007.002618
  13. Repossini A., Kotelnikov I., Bouchikhi R., Torre T., Passaretti B., Parodi O., Arena V. Single-suture line placement of a pericardial stentless valve. J Thorac Cardiovasc Surg. 2005;130(5):1265-9. PMID: 16256777. http://dx.doi.org/10.1016/j.jtcvs.2005.07.045
  14. van der Straaten E.P., Rademakers L.M., van Straten A.H., Houterman S., Tan M.E., Soliman Hamad M.A. Mid-term haemodynamic and clinical results after aortic valve replacement using the Freedom Solo stentless bioprosthesis versus the Carpentier Edwards Perimount stented bioprosthesis. Eur J Cardiothorac Surg. 2016;49(4):1174-80. PMID: 26224338. http://dx.doi.org/10.1093/ejcts/ezv255
  15. Beholz S., Repossini A., Livi U., Schepens M., Gabry M., Matschke K., Trivedi U., Eckel L., Dapunt O., Zamorano J. The Freedom SOLO valve for aortic valve replacement: clinical and hemodynamic results from a prospective multicenter trial. J Heart Valve Dis. 2010;19(1):23. PMID: 20329497.
  16. Vicchio M., Della Corte A., De Santo L., De Feo M., Caianiello G., Scardone M., Cotrufo M. Prosthesis patient mismatch in the elderly: survival, ventricular mass regression, and quality of life. Ann Thorac Surg. 2008;86(6):1791-7. PMID: 19021978. http://dx.doi.org/10.1016/j.athoracsur.2008.09.005
  17. Salizzoni S. Quality of life in patients with prosthesis–patient mismatch. J Thorac Cardiovasc Surg. 2009;138(3):786-7. http://dx.doi.org/10.1016/j.jtcvs.2009.04.036
  18. Sportelli E., Regesta T., Salsano A., Ghione P., Brega C., Bezante G., Passerone G., Santini F. Does patient-prosthesis mismatch after aortic valve replacement affect survival and quality of life in elderly patients? J Cardiovasc Med (Hagerstown). 2016;17(2):137-43. http://dx.doi.org/10.2459/JCM.0000000000000292