Vol. 19 No. 2 (2015)
CASE REPORTS

Giant pseudoaneurysm of aorta and aortobronchial fistula after surgery for aortic re-coarctation

I. Kornilov
Academician Ye. Meshalkin Novosibirsk Research Institute of Circulation Pathology, 15 Rechkunovskaya Str., 630055, Novosibirsk, Russian Federation
Bio
Yu. Sinelnikov
Federal Center of Cardiovascular Surgery, 35 Marshal Zhukov Str., 614000, Perm, Russian Federation
Bio
I. Soynov
Academician Ye. Meshalkin Novosibirsk Research Institute of Circulation Pathology, 15 Rechkunovskaya Str., 630055, Novosibirsk, Russian Federation
Bio
S. Ivantsov
Academician Ye. Meshalkin Novosibirsk Research Institute of Circulation Pathology, 15 Rechkunovskaya Str., 630055, Novosibirsk, Russian Federation
Bio
N. Nichay
Academician Ye. Meshalkin Novosibirsk Research Institute of Circulation Pathology, 15 Rechkunovskaya Str., 630055, Novosibirsk, Russian Federation
Bio
A. Omelchenko
Academician Ye. Meshalkin Novosibirsk Research Institute of Circulation Pathology, 15 Rechkunovskaya Str., 630055, Novosibirsk, Russian Federation
Bio
Yu. Gorbatykh
Academician Ye. Meshalkin Novosibirsk Research Institute of Circulation Pathology, 15 Rechkunovskaya Str., 630055, Novosibirsk, Russian Federation
Bio
A. Voitov
Academician Ye. Meshalkin Novosibirsk Research Institute of Circulation Pathology, 15 Rechkunovskaya Str., 630055, Novosibirsk, Russian Federation
Bio

Published 2015-07-17

Keywords

  • coarctation of the aorta,
  • pseudoaneurysm of aorta,
  • aortobronchial fistula

How to Cite

Kornilov, I., Sinelnikov, Y., Soynov, I., Ivantsov, S., Nichay, N., Omelchenko, A., Gorbatykh, Y., & Voitov, A. (2015). Giant pseudoaneurysm of aorta and aortobronchial fistula after surgery for aortic re-coarctation. Patologiya Krovoobrashcheniya I Kardiokhirurgiya, 19(2), 130–133. https://doi.org/10.21688/1681-3472-2015-2-130-133

Abstract

Aortobronchial fistula is a rare but potentially fatal complication after balloon plasty of aortic coarctation. We present a case of successful single-stage correction of giant pseudoaneurysm of the aortic arch with aortobronchial fistula in a 6-year-old patient after aortic arch replacement, which developed as a result of avulsion of the synthetic graft from the aortic wall when performing balloon angioplasty of a narrowed part of the aorta.

Received 15 April 2015. Accepted 30 April 2015.

References

  1. Brown J.W., Ruzmetov, Hoyer M.H. et al. // J. Ann Thorac. Surg. 2009. Vol. 88. P. 1923–1931.
  2. Oliver J. M., Gallego P., Gonzalez A. et al. // J. American College of Cardiology. 2004. Vol. 44. № 8. P. 1641–7.
  3. Rao P.S. // Br. Heart J. 1991. Vol. 66. № 5. P. 406–407.
  4. Balaji S., Oommen R., Rees P.G. // Br. Heart J. 1991. Vol. 65. P. 100–401.
  5. Brown M.L., Burkhart H.M., Connolly H.M. et al. // Circulation. 2010. Vol. 122. Р. 81–84.
  6. Синельников Ю.С., Кшановская М.С., Горбатых А.В., Иванцов С.М., Прохорова Д.С. Гипоплазия дуги аорты // Патология кровообращения и кардиохирургия. 2013. № 3. С. 68–72.
  7. Takawira F.F., Sinyangwe G., Mooloo R. // Heart Lung Circ. 2010. Vol. 19. № 12. Р. 745–748.
  8. Smayra T., Otal P., Soula P. et al. // J. Endovasc. Ther. 2001. Vol. 8. Р. 422–428.