Impact of extensive perfusion defects on the assessment of mechanical dyssynchrony indices using ECG-synchronized perfusion single-photon emission computed tomography of the myocardium
Published 2026-01-21
Keywords
- blood pool SPECT; ischemic heart failure; mechanical dyssynchrony; SPECT MPI
How to Cite
Copyright (c) 2026 Владимир Владимирович Шипулин, Анастасия Андреевна Маслова, Сергей Леонидович Андреев, Владимир Митрофанович Шипулин, Константин Валерьевич

This work is licensed under a Creative Commons Attribution 4.0 International License.
Abstract
Background: Assessment of left ventricular (LV) contractile function along with blood supply has recently become an increasingly common “extension” in the analysis of perfusion scintigraphy and single-photon emission computed tomography data, isolated or combined with myocardial X-ray computed tomography. It enables to reveal additional, more sensitive markers of various pathologies, one of which is mechanical dyssynchrony. However, in case of large
perfusion defects, this approach may provide unreliable information.
Objective: The study aimed at assessing the impact of extensive perfusion defects on the determination of mechanical dyssynchrony indices using ECG-synchronized perfusion single-photon emission computed tomography of myocardium.
Methods: Sixty-five patients with ischemic cardiomyopathy were included in the study. All patients were examined using ECG-synchronized myocardial perfusion scintigraphy and radionuclide tomoventriculography, as well as cardiac magnetic resonance imaging. All examinations were carried out in the resting state. Patients were assigned to two groups according to ECG-synchronized myocardial perfusion
scintigraphy data. Some formed a group with big perfusion defect relative to the
area of the LV in a state of functional rest (BDP; summed rest score ≥ 20%), while the others entered the group with minor defect of perfusion (MDP; summed rest score < 20%). The following parameters of LV contractile function were assessed using radionuclide modalities: ejection fraction (%), end-systolic (ml) and enddiastolic
(ml) volumes, as well as parameters of mechanical dyssynchrony (phase
histogram standard deviation (deg) and phase histogram bandwidth (deg)).
Magnetic resonance imaging as a reference method was used to assess ejection fraction, end-diastolic and end-systolic volumes of LV. The primary endpoint was summed rest score ≥ 20 %.
Results: The MDP group comprised 21 patients (summed rest score 11.7 (5.8;
16.1) %) and the BDP group amounted to 44 patients (summed rest score 30.8 (25; 41.1) %). In the MDP group, no differences in the estimated parameters between modalities were found. In the BDP group the parameters obtained by the ECGsynchronized myocardial perfusion scintigraphy differed significantly from those obtained by both radionuclide tomoventriculography and magnetic resonance imaging; whereas, no significant differences in the measured parameters were found
between radionuclide tomoventriculography and magnetic resonance imaging. The mechanical dyssynchrony indices in the BDP group were significantly higher
according to the data of ECG-synchronized myocardial perfusion scintigraphy compared to radionuclide tomoventriculography. According to Bland – Altman analysis, all
parameters did not show significant differences in the MDP group. Along with that, in the BDP group, volumes and mechanical dyssynchrony were significantly overestimated according to
ECG-synchronized myocardial perfusion scintigraphy data (mean differences end-diastolic volume 52.5 ml, end-systolic volume 35.9 ml, phase histogram standard deviation 7.9, phase
histogram bandwidth 67.2), while ejection fraction was underestimated (–3.4 %).
Conclusion: In patients with large (≥ 20 % of the LV myocardium area) perfusion defects, monitoring indices by the ECG-synchronized myocardial perfusion scintigraphy may lead to overestimation of LV mechanical dyssynchrony indices.
References
- Шипулин В.В., Саушкин В.В., Пряхин А.С., Андреев С.Л., Веснина Ж.В., Завадовский К.В. Возможности перфузионной сцинти- графии миокарда в обследовании пациентов с ишемической кардиомиопатией. Российский электронный журнал лучевой диагностики. 2019;9(3):155-175. https://doi.org/10.21569/2222-7415-2019-9-3-155-175 Shipulin V.V., Saushkin V.V., Pryakhin A.S., Andreev S.L., Vesnina Zh.V., Zavadovsky K.V. The value of myocardium perfusion imaging in assessment of patients with ischemic cardiomyopathy. REJR. 2019;9(3):155-175. (In Russ.) https://doi.org/10.21569/2222-7415-2019-9-3-155-175
- Саушкин В.В., Мишкина А.И., Шипулин В.В., Завадовский К.В. Значение радионуклидной оценки механической диссинхронии сердца в обследовании пациентов кардиологического профиля. Российский электронный журнал лучевой диагностики. 2019;9(1):186-202. https://doi.org/10.21569/2222-7415-2019-9-1-186-202 Saushkin V.V., Mishkina A.I., Shipulin V.V., Zavadovsky K.V. The value of radionuclide assessment of mechanical dyssynchrony in patients with cardiac diseases. REJR. 2019;9(1):186-202. (In Russ.) https://doi.org/10.21569/2222-7415-2019-9-1-186-202
- Links J.M., Douglass K.H., Wagner H.N. Jr. Patterns of ventricular emptying by Fourier analysis of gated blood-pool studies. J Nucl Med. 1980;21(10):978-82. PMID: 7420197.
- Chen J., Garcia E.V., Folks R.D., Cooke C.D., Faber T.L., Tauxe E.L., Iskandrian A.E. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12(6):687-95. PMID: 16344231. https://doi.org/10.1016/j.nuclcard.2005.06.088
- Allen LaPointe N.M., Ali-Ahmed F., Dalgaard F., Kosinski A.S., Sanders Schmidler G., Al-Khatib S.M. Cardiac resynchronization therapy outcomes with left ventricular lead concordant with latest mechanical activation: A meta-analysis. Pacing Clin Electrophysiol. 2022;45(8):930-939. PMID: 35687711; PMCID: PMC10752256. https://doi.org/10.1111/pace.14549
- Lee K., Han S., Ryu J., Cho S.G., Moon D.H. Prognostic value of left ventricular mechanical dyssynchrony indices derived from gated myocardial perfusion SPECT in coronary artery disease: a systematic review and meta-analysis. Ann Nucl Med. 2024;38(6):441-449. PMID: 38498236. https://doi.org/10.1007/s12149-024-01915-7
- Kuronuma K., Miller R.J.H., Otaki Y., Van Kriekinge S.D., Diniz M.A., Sharir T., Hu L.H., Gransar H., Liang J.X., Parekh T., Kavanagh P.B., Einstein A.J., Fish M.B., Ruddy T.D., Kaufmann P.A., Sinusas A.J., Miller E.J., Bateman T.M., Dorbala S., Di Carli M., Tamarappoo B.K., Dey D., Berman D.S., Slomka P.J. Prognostic Value of Phase Analysis for Predicting Adverse Cardiac Events Beyond Conventional Single- Photon Emission Computed Tomography Variables: Results From the REFINE SPECT Registry. Circ Cardiovasc Imaging. 2021;14(7):e012386. PMID: 34281372; PMCID: PMC8978932. https://doi.org/10.1161/CIRCIMAGING.120.012386
- Shipulin V.V., Andreev S., Kopeva K., Shipulin V.M., Zavadovsky K. The Value of Stress-Gated Blood Pool SPECT in Predicting Early Postoperative Period Complications in Ischemic Cardiomyopathy Patients: Focus on Mechanical Dyssynchrony. J Clin Med. 2023;12(16):5328. PMID: 37629370; PMCID: PMC10455889. https://doi.org/10.3390/jcm12165328
- Manrique A., Faraggi M., Véra P., Vilain D., Lebtahi R., Cribier A., Le Guludec D. 201Tl and 99mTc-MIBI gated SPECT in patients with large perfusion defects and left ventricular dysfunction: comparison with equilibrium radionuclide angiography. J Nucl Med. 1999;40(5):805-9. PMID: 10319754.
- Dorbala S., Ananthasubramaniam K., Armstrong I.S., Chareonthaitawee P., DePuey E.G., Einstein A.J., Gropler R.J., Holly T.A., Mahmarian J.J., Park M.A., Polk D.M., Russell R. 3rd, Slomka P.J., Thompson R.C., Wells R.G. Single Photon Emission Computed Tomography (SPECT) Myocardial Perfusion Imaging Guidelines: Instrumentation, Acquisition, Processing, and Interpretation. J Nucl Cardiol. 2018;25(5):1784-1846. PMID: 29802599. https://doi.org/10.1007/s12350-018-1283-y
- Farrell M.B., Galt J.R., Georgoulias P., Malhotra S., Pagnanelli R., Rischpler C., Savir-Baruch B. SNMMI Procedure Standard/EANM Guideline for Gated Equilibrium Radionuclide Angiography. J Nucl Med Technol. 2020;48(2):126-135. PMID: 32499322. https://doi.org/10.2967/jnmt.120.246405
- Shipulin V.V., Andreev S.L., Pryakhin A.S., Mochula A.V., Maltseva A.N., Sazonova S.I., Shipulin V.M., Massalha S., Zavadovsky K.V. Low- dose dobutamine stress gated blood pool SPECT assessment of left ventricular contractile reserve in ischemic cardiomyopathy: a feasibility study. Eur J Nucl Med Mol Imaging. 2022;49(7):2219-2231. PMID: 35150293. https://doi.org/10.1007/s00259-022-05714-y
- Heiberg E., Sjögren J., Ugander M., Carlsson M., Engblom H., Arheden H. Design and validation of Segment – freely available software for cardiovascular image analysis. BMC Med Imaging. 2010;10:1. PMID: 20064248; PMCID: PMC2822815. https://doi.org/10.1186/1471-2342-10-1
- Cochet H., Bullier E., Gerbaud E., Durieux M., Godbert Y., Lederlin M., Coste P., Barat J.L., Laurent F., Montaudon M. Absolute quantification of left ventricular global and regional function at nuclear MPI using ultrafast CZT SPECT: initial validation versus cardiac MR. J Nucl Med. 2013;54(4):556-63. PMID: 23385955. https://doi.org/10.2967/jnumed.112.110577
- Schaefer W.M., Lipke C.S., Standke D., Kühl H.P., Nowak B., Kaiser H.J., Koch K.C., Buell U. Quantification of left ventricular volumes and ejection fraction from gated 99mTc-MIBI SPECT: MRI validation and comparison of the Emory Cardiac Tool Box with QGS and 4D- MSPECT. J Nucl Med. 2005;46(8):1256-63. PMID: 16085580.
- Apert A., Canu M., Jankowski A., Riou L., Broisat A., Charlon C., Augier C., Boignard A., Leenhardt J., Salvat M., Casset C., Maurin M., Saunier C., Vanzetto G., Fagret D., Ghezzi C., Djaileb L., Barone- Rochette G. Comparison of Cadmium Zinc Telluride ECG-gated SPECT equilibrium radionuclide angiocardiography to magnetic resonance imaging to measure right ventricular volumes and ejection fraction in patients with cardiomyopathy. J Nucl Cardiol. 2022;29(4):1647-1656. PMID: 33988809. https://doi.org/10.1007/s12350-021-02653-3
- Singhal A., Khangembam B.C., Seth S., Patel C. Equilibrium Radionuclide Angiography in Evaluation of Left Ventricular Mechanical Dyssynchrony in Patients with Dilated Cardiomyopathy: Comparison with Electrocardiographic Parameters and Speckle- Tracking Echocardiography. Indian J Nucl Med. 2019;34(2):88-95. PMID: 31040518; PMCID: PMC6481198. https://doi.org/10.4103/ijnm.IJNM_165_18
- Chen Y., Xue X., Gu Y., Xu H., Zhang X. Equilibrium radionuclide angiography compared with tissue doppler imaging for detection of right ventricular dyssynchrony and prediction of acute response to cardiac resynchronization therapy. Medicine (Baltimore). 2020;99(9):e19296. PMID: 32118744; PMCID: PMC7478515. https://doi.org/10.1097/MD.0000000000019296
- Kita A., Onoguchi M., Shibutani T., Sugimoto K., Kosaka N., Adachi T., Kimura H. Influence of myocardial count on phase dyssynchrony analysis of gated myocardial perfusion single-photon emission computed tomography. Nucl Med Commun. 2019;40(2):124-130. PMID: 30461698. https://doi.org/10.1097/MNM.0000000000000949
- Шипулин В.М., Пряхин А.С., Андреев С.Л., Шипулин В.В., Чумакова С.П., Рябова Т.Р., Стельмашенко А.И., Беляева С.А., Лелик Е.В. Современные клинико-фундаментальные аспекты в диагно- стике и лечении пациентов с ишемической кардиомиопатией (обзор). Сибирский журнал клинической и экспериментальной медицины. 2021;36(1):20-29. https://doi.org/10.29001/2073-8552-2021-36-1-20-29 Shipulin V.M., Pryakhin A.S., Andreev S.L., Shipulin V.V.,Chumakova S.P., Ryabova T.R., Stelmashenko A.I., Belyaeva S.A., Lelik E.V. Modern clinical and fundamental aspects in the diagnosis and treatment of patients with ischemic cardiomyopathy (Review). The Siberian Journal of Clinical and Experimental Medicine. 2021;36(1):20-29. (In Russ.) https://doi.org/10.29001/2073-8552-2021-36-1-20-29
- Okuda K., Nakajima K., Matsuo S., Kashiwaya S., Yoneyama H., Shibutani T., Onoguchi M., Hashimoto M., Kinuya S. Comparison of diagnostic performance of four software packages for phase dyssynchrony analysis in gated myocardial perfusion SPECT. EJNMMI Res. 2017;7(1):27. PMID: 28337725; PMCID: PMC5364119. https://doi.org/10.1186/s13550-017-0274-3
- de Amorim Fernandes F., Peix A., Giubbini R., Karthikeyan G., Massardo T., Patel C., Pabon L.M., Jimenez-Heffernan A., Alexanderson E., Butt S., Kumar A., Marin V., Morozova O., Paez D., Mesquita C.T., Garcia E.V. Reproducibility of global LV function and dyssynchrony parameters derived from phase analysis of gated myocardial perfusion SPECT: A multicenter comparison with core laboratorysetting.JNuclCardiol.2022;29(3):952-961.PMID:33083983. https://doi.org/10.1007/s12350-020-02397-6
- Legallois D., Marie P.Y., Franken P.R., Djaballah W., Agostini D., Manrique A. Comparison of the dyssynchrony parameters recorded with gated SPECT in ischemic cardiomyopathy according to their repeatability at rest and to their ability to detect a synchrony reserve under dobutamine infusion. J Nucl Cardiol. 2020;27(6):2247-2257. PMID: 30515748. https://doi.org/10.1007/s12350-018-01546-2
- Salimian S., Thibault B., Finnerty V., Grégoire J., Harel F. Phase analysis of gated blood pool SPECT for multiple stress testing assessments of ventricular mechanical dyssynchrony in a tachycardia-induced dilated cardiomyopathy canine model. J Nucl Cardiol. 2017;24(1):145-157. PMID: 26686363. https://doi.org/10.1007/s12350-015-0338-6
- Trimble M.A., Velazquez E.J., Adams G.L., Honeycutt E.F., Pagnanelli R.A., Barnhart H.X., Chen J., Iskandrian A.E., Garcia E.V., Borges-Neto S. Repeatability and reproducibility of phase analysis of gated single-photon emission computed tomography myocardial perfusion imaging used to quantify cardiac dyssynchrony. Nucl Med Commun. 2008;29(4):374-81. PMID: 18317303; PMCID: PMC3048057. https://doi.org/10.1097/MNM.0b013e3282f81380
