<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with OASIS Tables with MathML3 v1.4 20241031//EN" "https://jats.nlm.nih.gov/archiving/1.4/JATS-archive-oasis-article1-4-mathml3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:ali="http://www.niso.org/schemas/ali/1.0/" dtd-version="1.4" article-type="research-article" xml:lang="en"><front><journal-meta><journal-title-group><journal-title xml:lang="ru">Патология кровообращения и кардиохирургия</journal-title></journal-title-group><issn publication-format="print">1681-3472</issn><issn publication-format="electronic">2500-3119</issn></journal-meta><article-meta><article-id pub-id-type="doi">10.21688/1681-3472-2026-3-49-56</article-id><article-categories><subj-group><subject>Other</subject></subj-group></article-categories><title-group><article-title xml:lang="ru">Эхокардиографический подход при эндоваскулярном закрытии дефектов межпредсердной перегородки у детей с дефицитом или отсутствием аортального края: ретроспективный анализ</article-title><trans-title-group xml:lang="en"><trans-title>Echocardiographic approach to transcatheter closure of atrial septal defects in children with a deficient or absent aortic rim: a retrospective analysis</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Курако</surname><given-names>М. М.</given-names></name><name xml:lang="en"><surname>Kurako</surname><given-names>Mariya M.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff1"/><xref ref-type="aff" rid="aff2"/><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-1100-1506</contrib-id></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Абрамян</surname><given-names>М. А.</given-names></name><name xml:lang="en"><surname>Abramyan</surname><given-names>Mikhail A.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff3"/><xref ref-type="aff" rid="aff4"/><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-4018-6287</contrib-id></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Кулагина</surname><given-names>Т. Ю.</given-names></name><name xml:lang="en"><surname>Kulagina</surname><given-names>Tatyana Yu.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff5"/><xref ref-type="aff" rid="aff6"/><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-6165-6474</contrib-id></contrib><contrib contrib-type="author"><name-alternatives><name xml:lang="ru"><surname>Пурсанов</surname><given-names>М. Г.</given-names></name><name xml:lang="en"><surname>Pursanov</surname><given-names>Manolis G.</given-names></name></name-alternatives><xref ref-type="aff" rid="aff1"/><xref ref-type="aff" rid="aff7"/><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0002-1421-1795</contrib-id></contrib><aff-alternatives id="aff1"><aff><institution xml:lang="en">Morozov Children’s City Clinical Hospital</institution><city xml:lang="en">Moscow</city><country xml:lang="en">Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff2"><aff><institution xml:lang="ru">Государственное бюджетное учреждение здравоохранения города Москвы «Морозовская детская городская клиническая больница Департамента здравоохранения города Москвы», Москва, Российская Федерация;</institution><city xml:lang="ru">Москва</city><country xml:lang="ru">Российская Федерация</country></aff></aff-alternatives><aff-alternatives id="aff3"><aff><institution xml:lang="en">Morozov Children’s City Clinical Hospital, Moscow;  Patrice Lumumba Peoples’ Friendship University of Russia</institution><city xml:lang="en">Moscow</city><country xml:lang="en">Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff4"><aff><institution xml:lang="ru">Государственное бюджетное учреждение здравоохранения города Москвы «Морозовская детская городская клиническая больница Департамента здравоохранения города Москвы», Москва, Российская Федерация; Федеральное государственное автономное образовательное учреждение высшего образования «Российский университет дружбы народов имени Патриса Лумумбы», Москва, Российская Федерация</institution><city xml:lang="ru">Москва</city><country xml:lang="ru">Российская Федерацияя</country></aff></aff-alternatives><aff-alternatives id="aff5"><aff><institution xml:lang="en">Petrovsky National Research Center of Surgery</institution><city xml:lang="en">Moscow</city><country xml:lang="en">Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff6"><aff><institution xml:lang="ru">Государственный научный центр Российской Федерации Федеральное государственное бюджетное научное учреждение «Российский научный центр хирургии имени академика Б.В. Петровского», Москва, Российская Федерация</institution><city xml:lang="ru">Москва</city><country xml:lang="ru">Российская Федерация</country></aff></aff-alternatives><aff-alternatives id="aff7"><aff><institution xml:lang="ru">Государственное бюджетное учреждение здравоохранения города Москвы «Морозовская детская городская клиническая больница Департамента здравоохранения города Москвы», Москва, Российская Федерация</institution><city xml:lang="ru">Москва</city><country xml:lang="ru">Российская Федерация</country></aff></aff-alternatives></contrib-group><pub-date pub-type="epub" iso-8601-date="2026-10-21"><day>21</day><month>10</month><year>2026</year></pub-date><volume>30</volume><issue>3</issue><fpage>49</fpage><lpage>56</lpage><history><date date-type="received" iso-8601-date="2026-03-17"><day>17</day><month>03</month><year>2026</year></date><date date-type="accepted" iso-8601-date="2026-06-23"><day>23</day><month>06</month><year>2026</year></date></history><permissions><license xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:title="CC BY 4.0"><ali:license_ref>https://creativecommons.org/licenses/by/4.0/</ali:license_ref><license-p xml:lang="ru">CC BY 4.0</license-p></license></permissions><self-uri xlink:href="https://journal.meshalkin.ru/index.php/heartjournal/article/view/1415" xlink:title="https://journal.meshalkin.ru/index.php/heartjournal/article/view/1415">https://journal.meshalkin.ru/index.php/heartjournal/article/view/1415</self-uri><self-uri content-type="pdf" xlink:href="publication-3481536e-5de6-488a-9ec7-80dca99e5408.pdf" xlink:title="PDF"/><abstract xml:lang="ru"><p>Актуальность. Эндоваскулярное закрытие вторичных дефектов межпредсердной перегородки (ДМПП) является стандартом лечения, однако случаи с дефицитом или отсутствием аортального края остаются технически сложными из-за риска развития эрозии стенки аорты или крыши предсердия. Несмотря на наличие обширной мировой статистики, в отечественной практике методики безопасного закрытия таких дефектов у детей изучены недостаточно. Цель. Разработка и оценка эффективности дифференцированного алгоритма подбора окклюдера на основе комплексной эхокардиографической визуализации для минимизации рисков при транскатетерном закрытии ДМПП с дефицитом аортального края у детей. Методы. Проведен ретроспективный анализ результатов лечения 265 детей с изолированным дефицитом или полным отсутствием аортального края. Ведущим инструментом контроля на всех этапах выступали трансторакальная (ТТЭХОКГ) и чреспищеводная эхокардиография (ЧПЭХОКГ). Применялся персонализированный подход к выбору размера устройства: при плотных краях размер определялся по данным эхокардиографии с цветным допплеровским картированием, при истонченных – техникой stop-flow. Особое внимание уделялось индексу соразмерности (диаметр устройства / масса тела пациента). Результаты. Среднее значение индекса соразмерности в исследуемой группе составило 0,88, что позволило избежать чрезмерного давления на структуры сердца. Внедрение дифференцированного алгоритма (выбор размера окклюдера от –2 до +2 мм в зависимости от эхо-картины краев) обеспечило высокую техническую успешность вмешательств. За весь период наблюдения (Ме = 38 мес., [IQR]: 24–52 мес.; диапазон: от 6 до 84 мес.) не было зафиксировано ни одного случая эрозии аорты или других жизнеугрожающих осложнений. Заключение. Транскатетерное закрытие ДМПП при дефиците аортального края у детей является безопасным методом при условии строгого соблюдения протокола визуализации и корректного подбора размера окклюдера. Использование предложенного алгоритма и контроль индекса соразмерности минимизируют механическое воздействие на корень аорты, обеспечивая отличные клинические результаты. Поступила в редакцию 17 марта 2026 г. Исправлена 17 июня 2026 г. Принята к печати 23 июня 2026 г.</p></abstract><abstract xml:lang="en" abstract-type="summary"><p>Introduction: Transcatheter closure of secundum atrial septal defects (ASDs) is the standard of care. However, defects with a deficient or absent aortic rim remain technically challenging because of the risk of erosion of the aortic wall or atrial roof. Despite extensive international experience, techniques for the safe closure of such defects in children remain insufficiently studied in Russian clinical practice. Objective: To develop and evaluate the effectiveness of a differentiated occludersizing algorithm based on comprehensive echocardiographic imaging to minimize the risks of transcatheter ASD closure in children with a deficient aortic rim. Methods: A retrospective analysis was performed in 265 children with an isolated deficient or completely absent aortic rim. Transthoracic (TTE) and transesophageal echocardiography (TEE) were the principal imaging modalities used for monitoring at all stages of the procedure. A personalized approach to device sizing was applied: in patients with firm rims, device size was determined using echocardiography with color Doppler mapping; in patients with thin rims, the stop-flow technique was used. Particular attention was paid to the device-to-body-weight ratio (device diameter/ body weight). Results: The mean device-to-body-weight ratio in the study group was 0.88, which helped avoid excessive pressure on cardiac structures. Implementation of the differentiated algorithm, involving selection of an occluder 2 mm smaller to 2 mm larger than the measured size depending on the echocardiographic appearance of the rims, resulted in a high technical success rate. During the entire follow-up period (median, 38 months; interquartile range [IQR], 24–52 months; range, 6–84 months), there were no cases of aortic erosion or other life-threatening complications. Conclusion: Transcatheter ASD closure in children with a deficient aortic rim is a safe procedure provided that the imaging protocol is strictly followed and the occluder is appropriately sized. The proposed algorithm and monitoring of the device-to-bodyweight ratio minimize mechanical stress on the aortic root and provide excellent clinical outcomes. Received 17 March 2026. Revised 17 June 2026. Accepted 23 June 2026.</p></abstract><kwd-group xml:lang="ru"><kwd>дефект межпредсердной перегородки</kwd><kwd>дефицит аортального края</kwd><kwd>окклюдер</kwd><kwd>техника stop-flow</kwd><kwd>эндоваскулярная хирургия</kwd><kwd>эрозия стенки предсердия и аорты</kwd><kwd>эхокардиография</kwd></kwd-group><funding-group><funding-statement xml:lang="ru">Исследование не имело спонсорской поддержки.</funding-statement><funding-statement xml:lang="en">The study did not have sponsorship.</funding-statement></funding-group></article-meta></front><back><ref-list><ref id="ref1"><mixed-citation publication-type="other" xml:lang="ru">Rigatelli G., Gianese F., Zuin M. Secundum Atrial Septal Defects Transcatheter Closure: An Updated Reappraisal. Cardiovasc Revasc Med. 2022;44:92-97. PMID: 35680528. https://doi.org/10.1016/j.carrev.2022.06.002</mixed-citation></ref><ref id="ref2"><mixed-citation publication-type="other" xml:lang="ru">Сойнов И.А., Ким А.И., Мовсесян Р.Р., Теплов П.В., Миллер А.Ю., Кулябин Ю.Ю., Авраменко А.А., Горбатиков К.В., Горбатых А.В., Налимов К.А., Абрамян М.А., Борисков М.В., Ковалев С.А., Свободов А.А., Архипов А.Н., Кривощеков Е.В., Амансахатова Е.Н., Тарасюк Е.С. Хирургическое лечение врожденных пороков сердца в Российской Федерации: данные национального регистра за 2024 год. Патология кровообращения и кардиохирургия. 2026;30(1):5-25. Soynov I.A., Kim A.I., Movsesyan R.R., Teplov P.V., Miller A.Yu., Kulyabin Yu.Yu., Avramenko A.A., Gorbatikov K.V., Gorbatykh A.V., Nalimov K.A., Abramyan M.A., Boriskov M.V., Kovalev S.A., Svobodov A.A., Arkhipov A.N., Krivoshchekov E.V., Amansakhatova E.N., Tarasyuk E.S. Surgical Management of congenital heart diseases in the Russian Federation: national registry data for 2024. Patologiya krovoobrashcheniya i kardiokhirurgiya = Circulation Pathology and Cardiac Surgery. 2026;30(1):5-25. (In Russ.) https://doi.org/10.21688/1681-3472-2026-1-5-25</mixed-citation></ref><ref id="ref3"><mixed-citation publication-type="other" xml:lang="ru">Silvestry F.E., Cohen M.S., Armsby L.B., Burkule N.J., Fleishman C.E., Hijazi Z.M., Lang R.M., Rome J.J., Wang Y.; American Society of Echocardiography; Society for Cardiac Angiography and Interventions. Guidelines for the Echocardiographic Assessment of Atrial Septal Defect and Patent Foramen Ovale: From the American Society of Echocardiography and Society for Cardiac Angiography and Interventions. J Am Soc Echocardiogr. 2015;28(8):910-58. PMID: 26239900. https://doi.org/10.1016/j.echo.2015.05.015</mixed-citation></ref><ref id="ref4"><mixed-citation publication-type="other" xml:lang="ru">Amin Z., Hijazi Z.M., Bass J.L., Cheatham J.P., Hellenbrand W.E., Kleinman C.S. Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv. 2004;63(4):496-502. PMID: 15558755. https://doi.org/10.1002/ccd.20211</mixed-citation></ref><ref id="ref5"><mixed-citation publication-type="other" xml:lang="ru">Crawford G.B., Brindis R.G., Krucoff M.W., Mansalis B.P., Carroll J.D. Percutaneous atrial septal occluder devices and cardiac erosion: a review of the literature. Catheter Cardiovasc Interv. 2012;80(2):157-67. PMID: 22552868. https://doi.org/10.1002/ccd.24347</mixed-citation></ref><ref id="ref6"><mixed-citation publication-type="other" xml:lang="ru">Jalal Z., Hascoet S., Baruteau A.E., Iriart X., Kreitmann B., Boudjemline Y., Thambo J.B. Long-term Complications After Transcatheter Atrial Septal Defect Closure: A Review of the Medical Literature. Can J Cardiol. 2016;32(11):1315.e11-1315.e18. PMID: 27179546. https://doi.org/10.1016/j.cjca.2016.02.068</mixed-citation></ref><ref id="ref7"><mixed-citation publication-type="other" xml:lang="ru">Auriau J., Bouvaist H., Aaberge L., Abe T., Dahnert I., Panzer J., Santoro G., Khalil M., Hijazi Z.M., Fraisse A. Cardiac Erosions After Transcatheter Atrial Septal Defect Closure With the Occlutech Figulla Flex Device. JACC Cardiovasc Interv. 2019;12(14):1397-1399. PMID: 31320034. https://doi.org/10.1016/j.jcin.2019.03.005</mixed-citation></ref><ref id="ref8"><mixed-citation publication-type="other" xml:lang="ru">Diab K., Kenny D., Hijazi Z.M. Erosions, erosions, and erosions! Device closure of atrial septal defects: how safe is safe? Catheter Cardiovasc Interv. 2012;80(2):168-74. PMID: 22718680. https://doi.org/10.1002/ccd.24517</mixed-citation></ref><ref id="ref9"><mixed-citation publication-type="other" xml:lang="ru">Zhang Z.Q., Ding J.W. Perforation of the atrial wall and aortic sinus after closure of an atrial septal defect with an Atriasept occluder: a case report. J Cardiothorac Surg. 2021;16(1):53. PMID: 33766059; PMCID: PMC7993524. https://doi.org/10.1186/s13019-021-01441-x</mixed-citation></ref><ref id="ref10"><mixed-citation publication-type="other" xml:lang="ru">Kitano M., Yazaki S., Sugiyama H., Ohtsuki S.I., Tomita H. Risk factors and predictors of cardiac erosion discovered from 12 Japanese patients who developed erosion after atrial septal defect closure using Amplatzer septal occluder. Pediatr Cardiol. 2020;41(2):297-308. PMID: 31732763. https://doi.org/10.1007/s00246-019-02256-3</mixed-citation></ref><ref id="ref11"><mixed-citation publication-type="other" xml:lang="ru">Nakayama R., Takaya Y., Akagi T., Watanabe N., Miki T., Nakagawa K., Toh N., Ito H. Efficacy and safety of atrial septal defect closure using Occlutech Figulla Flex II compared with Amplatzer Septal Occluder. Heart Vessels. 2021;36(5):704-709. PMID: 33386412. https://doi.org/10.1007/s00380-020-01739-1</mixed-citation></ref><ref id="ref12"><mixed-citation publication-type="other" xml:lang="ru">Baruteau A.E., Petit J., Lambert V., Gouton M., Piot D., Brenot P., Angel C.Y., Houyel L., Le Bret E., Roussin R., Ly M., Capderou A., Belli E. Transcatheter closure of large atrial septal defects: feasibility and safety in a large adult and pediatric population. Circ Cardiovasc Interv. 2014;7(6):837-43. PMID: 25423959. https://doi.org/10.1161/CIRCINTERVENTIONS.113.001254</mixed-citation></ref><ref id="ref13"><mixed-citation publication-type="other" xml:lang="ru">Tanghoj G., Odermarsky M., Naumburg E., Liuba P. Correction to: Early Complications After Percutaneous Closure of Atrial Septal Defect in Infants with Procedural Weight Less than 15 kg. Pediatr Cardiol. 2021;42(2):468. PMID: 33575831; PMCID: PMC8025282. https://doi.org/10.1007/s00246-021-02550-z</mixed-citation></ref><ref id="ref14"><mixed-citation publication-type="other" xml:lang="ru">Turner D.R., Owada C.Y., Sang C.J. Jr, Khan M., Lim D.S. Closure of Secundum Atrial Septal Defects With the AMPLATZER Septal Occluder: a Prospective, Multicenter, Post-Approval Study. Circ Cardiovasc Interv. 2017;10(8):e004212. PMID: 28801537; PMCID: PMC5559192. https://doi.org/10.1161/CIRCINTERVENTIONS.116.004212</mixed-citation></ref><ref id="ref15"><mixed-citation publication-type="other" xml:lang="ru">Kenny D., Eicken A., Dahnert I., Boudjemline Y., Sievert H., Schneider M.B., Gori T., Hijazi Z.M.; Investigators. A randomized, controlled, multi-center trial of the efficacy and safety of the Occlutech Figulla Flex-II Occluder compared to the Amplatzer Septal Occluder for transcatheter closure of secundum atrial septal defects. Catheter Cardiovasc Interv. 2019;93(2):316-321. PMID: 30719850. https://doi.org/10.1002/ccd.27899</mixed-citation></ref><ref id="ref16"><mixed-citation publication-type="other" xml:lang="ru">Onakatomi Y., Asou T., Takeda Y., Ueda H., Goda M., Masuda M. Aortic erosion occurring in over 5 years after Amplatzer septal Occluder implantation for secundum atrial septal defect: a case report. J Cardiothorac Surg. 2019;14(1):159. PMID: 31492164; PMCID: PMC6728993. https://doi.org/10.1186/s13019-019-0982-z</mixed-citation></ref><ref id="ref17"><mixed-citation publication-type="other" xml:lang="ru">Dardas P.S., Ninios V.N., Mezilis N.E., Tsikaderis D.D., Thanopoulos V.D. Percutaneous closure of atrial septal defects: immediate and mid-term results. Hellenic J Cardiol. 2010;51(2):104-12. PMID: 20378511.</mixed-citation></ref><ref id="ref18"><mixed-citation publication-type="other" xml:lang="ru">El-Said H.G., Moore J.W. Erosion by the Amplatzer septal occluder: experienced operator opinions at odds with manufacturer recommendations? Catheter Cardiovasc Interv. 2009;73(7):925-30. PMID: 19455668. https://doi.org/10.1002/ccd.21931</mixed-citation></ref><ref id="ref19"><mixed-citation publication-type="other" xml:lang="ru">Roymanee S., Promphan W., Tonklang N., Wongwaitaweewong K. Comparison of the Occlutech Figulla septal occluder and Amplatzer septal occluder for atrial septal defect device closure. Pediatric Cardiology. 2015;36(5):935-41. PMID: 25633819. https://doi.org/10.1007/s00246-015-1103-y</mixed-citation></ref><ref id="ref20"><mixed-citation publication-type="other" xml:lang="ru">Takaya Y., Akagi T., Nakagawa K., Nakayama R., Miki T., Toh N., Ito H. Feasibility of transcatheter closure for absent aortic rim in patients with atrial septal defect. Catheter Cardiovasc Interv. 2021;97(5):859-864. PMID: 33458916. https://doi.org/10.1002/ccd.29457</mixed-citation></ref><ref id="ref21"><mixed-citation publication-type="other" xml:lang="ru">Rao P.S., Harris A.D. Recent advances in managing septal defects: atrial septal defects. F1000Res. 2017;6:2042. PMID: 29250321; PMCID: PMC5701442. https://doi.org/10.12688/f1000research.11844.1</mixed-citation></ref><ref id="ref22"><mixed-citation publication-type="other" xml:lang="ru">Shrivastava S., Shrivastava S., Allu S.V.V., Schmidt P. Transcatheter Closure of Atrial Septal Defect: A Review of Currently Used Devices. Cureus. 2023;15(6):e40132. PMID: 37425612; PMCID: PMC10329454. https://doi.org/10.7759/cureus.40132</mixed-citation></ref><ref id="ref23"><mixed-citation publication-type="other" xml:lang="ru">Boccalandro F., Baptista E., Muench A., Carter C., Smalling R.W. Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect. Am J Cardiol. 2004;93(4):437-40. PMID: 14969617. https://doi.org/10.1016/j.amjcard.2003.10.037</mixed-citation></ref><ref id="ref24"><mixed-citation publication-type="other" xml:lang="ru">Ohno N., Chaturvedi R., Lee K.J., Benson L. Characteristics of secundum atrial septal defects not percutaneously closed. Catheter Cardiovasc Interv. 2015;85(2):234-9. PMID: 25315692. https://doi.org/10.1002/ccd.25700</mixed-citation></ref><ref id="ref25"><mixed-citation publication-type="other" xml:lang="ru">Jung S.Y., Choi J.Y. Transcatheter closure of atrial septal defect: principles and available devices. J Thorac Dis. 2018;10(Suppl 24):S2909-S2922. PMID: 30305951; PMCID: PMC6174149. https://doi.org/10.21037/jtd.2018.02.19</mixed-citation></ref><ref id="ref26"><mixed-citation publication-type="other" xml:lang="en">Rigatelli G., Gianese F., Zuin M. Secundum Atrial Septal Defects Transcatheter Closure: An Updated Reappraisal. Cardiovasc Revasc Med. 2022;44:92-97. PMID: 35680528. https://doi.org/10.1016/j.carrev.2022.06.002</mixed-citation></ref><ref id="ref27"><mixed-citation publication-type="other" xml:lang="en">Сойнов И.А., Ким А.И., Мовсесян Р.Р., Теплов П.В., Миллер А.Ю., Кулябин Ю.Ю., Авраменко А.А., Горбатиков К.В., Горбатых А.В., Налимов К.А., Абрамян М.А., Борисков М.В., Ковалев С.А., Свободов А.А., Архипов А.Н., Кривощеков Е.В., Амансахатова Е.Н., Тарасюк Е.С. Хирургическое лечение врожденных пороков сердца в Российской Федерации: данные национального регистра за 2024 год. Патология кровообращения и кардиохирургия. 2026;30(1):5-25. Soynov I.A., Kim A.I., Movsesyan R.R., Teplov P.V., Miller A.Yu., Kulyabin Yu.Yu., Avramenko A.A., Gorbatikov K.V., Gorbatykh A.V., Nalimov K.A., Abramyan M.A., Boriskov M.V., Kovalev S.A., Svobodov A.A., Arkhipov A.N., Krivoshchekov E.V., Amansakhatova E.N., Tarasyuk E.S. Surgical Management of congenital heart diseases in the Russian Federation: national registry data for 2024. Patologiya krovoobrashcheniya i kardiokhirurgiya = Circulation Pathology and Cardiac Surgery. 2026;30(1):5-25. (In Russ.) https://doi.org/10.21688/1681-3472-2026-1-5-25</mixed-citation></ref><ref id="ref28"><mixed-citation publication-type="other" xml:lang="en">Silvestry F.E., Cohen M.S., Armsby L.B., Burkule N.J., Fleishman C.E., Hijazi Z.M., Lang R.M., Rome J.J., Wang Y.; American Society of Echocardiography; Society for Cardiac Angiography and Interventions. Guidelines for the Echocardiographic Assessment of Atrial Septal Defect and Patent Foramen Ovale: From the American Society of Echocardiography and Society for Cardiac Angiography and Interventions. J Am Soc Echocardiogr. 2015;28(8):910-58. PMID: 26239900. https://doi.org/10.1016/j.echo.2015.05.015</mixed-citation></ref><ref id="ref29"><mixed-citation publication-type="other" xml:lang="en">Amin Z., Hijazi Z.M., Bass J.L., Cheatham J.P., Hellenbrand W.E., Kleinman C.S. Erosion of Amplatzer septal occluder device after closure of secundum atrial septal defects: review of registry of complications and recommendations to minimize future risk. Catheter Cardiovasc Interv. 2004;63(4):496-502. PMID: 15558755. https://doi.org/10.1002/ccd.20211</mixed-citation></ref><ref id="ref30"><mixed-citation publication-type="other" xml:lang="en">Crawford G.B., Brindis R.G., Krucoff M.W., Mansalis B.P., Carroll J.D. Percutaneous atrial septal occluder devices and cardiac erosion: a review of the literature. Catheter Cardiovasc Interv. 2012;80(2):157-67. PMID: 22552868. https://doi.org/10.1002/ccd.24347</mixed-citation></ref><ref id="ref31"><mixed-citation publication-type="other" xml:lang="en">Jalal Z., Hascoet S., Baruteau A.E., Iriart X., Kreitmann B., Boudjemline Y., Thambo J.B. Long-term Complications After Transcatheter Atrial Septal Defect Closure: A Review of the Medical Literature. Can J Cardiol. 2016;32(11):1315.e11-1315.e18. PMID: 27179546. https://doi.org/10.1016/j.cjca.2016.02.068</mixed-citation></ref><ref id="ref32"><mixed-citation publication-type="other" xml:lang="en">Auriau J., Bouvaist H., Aaberge L., Abe T., Dahnert I., Panzer J., Santoro G., Khalil M., Hijazi Z.M., Fraisse A. Cardiac Erosions After Transcatheter Atrial Septal Defect Closure With the Occlutech Figulla Flex Device. JACC Cardiovasc Interv. 2019;12(14):1397-1399. PMID: 31320034. https://doi.org/10.1016/j.jcin.2019.03.005</mixed-citation></ref><ref id="ref33"><mixed-citation publication-type="other" xml:lang="en">Diab K., Kenny D., Hijazi Z.M. Erosions, erosions, and erosions! Device closure of atrial septal defects: how safe is safe? Catheter Cardiovasc Interv. 2012;80(2):168-74. PMID: 22718680. https://doi.org/10.1002/ccd.24517</mixed-citation></ref><ref id="ref34"><mixed-citation publication-type="other" xml:lang="en">Zhang Z.Q., Ding J.W. Perforation of the atrial wall and aortic sinus after closure of an atrial septal defect with an Atriasept occluder: a case report. J Cardiothorac Surg. 2021;16(1):53. PMID: 33766059; PMCID: PMC7993524. https://doi.org/10.1186/s13019-021-01441-x</mixed-citation></ref><ref id="ref35"><mixed-citation publication-type="other" xml:lang="en">Kitano M., Yazaki S., Sugiyama H., Ohtsuki S.I., Tomita H. Risk factors and predictors of cardiac erosion discovered from 12 Japanese patients who developed erosion after atrial septal defect closure using Amplatzer septal occluder. Pediatr Cardiol. 2020;41(2):297-308. PMID: 31732763. https://doi.org/10.1007/s00246-019-02256-3</mixed-citation></ref><ref id="ref36"><mixed-citation publication-type="other" xml:lang="en">Nakayama R., Takaya Y., Akagi T., Watanabe N., Miki T., Nakagawa K., Toh N., Ito H. Efficacy and safety of atrial septal defect closure using Occlutech Figulla Flex II compared with Amplatzer Septal Occluder. Heart Vessels. 2021;36(5):704-709. PMID: 33386412. https://doi.org/10.1007/s00380-020-01739-1</mixed-citation></ref><ref id="ref37"><mixed-citation publication-type="other" xml:lang="en">Baruteau A.E., Petit J., Lambert V., Gouton M., Piot D., Brenot P., Angel C.Y., Houyel L., Le Bret E., Roussin R., Ly M., Capderou A., Belli E. Transcatheter closure of large atrial septal defects: feasibility and safety in a large adult and pediatric population. Circ Cardiovasc Interv. 2014;7(6):837-43. PMID: 25423959. https://doi.org/10.1161/CIRCINTERVENTIONS.113.001254</mixed-citation></ref><ref id="ref38"><mixed-citation publication-type="other" xml:lang="en">Tanghoj G., Odermarsky M., Naumburg E., Liuba P. Correction to: Early Complications After Percutaneous Closure of Atrial Septal Defect in Infants with Procedural Weight Less than 15 kg. Pediatr Cardiol. 2021;42(2):468. PMID: 33575831; PMCID: PMC8025282. https://doi.org/10.1007/s00246-021-02550-z</mixed-citation></ref><ref id="ref39"><mixed-citation publication-type="other" xml:lang="en">Turner D.R., Owada C.Y., Sang C.J. Jr, Khan M., Lim D.S. Closure of Secundum Atrial Septal Defects With the AMPLATZER Septal Occluder: a Prospective, Multicenter, Post-Approval Study. Circ Cardiovasc Interv. 2017;10(8):e004212. PMID: 28801537; PMCID: PMC5559192. https://doi.org/10.1161/CIRCINTERVENTIONS.116.004212</mixed-citation></ref><ref id="ref40"><mixed-citation publication-type="other" xml:lang="en">Kenny D., Eicken A., Dahnert I., Boudjemline Y., Sievert H., Schneider M.B., Gori T., Hijazi Z.M.; Investigators. A randomized, controlled, multi-center trial of the efficacy and safety of the Occlutech Figulla Flex-II Occluder compared to the Amplatzer Septal Occluder for transcatheter closure of secundum atrial septal defects. Catheter Cardiovasc Interv. 2019;93(2):316-321. PMID: 30719850. https://doi.org/10.1002/ccd.27899</mixed-citation></ref><ref id="ref41"><mixed-citation publication-type="other" xml:lang="en">Onakatomi Y., Asou T., Takeda Y., Ueda H., Goda M., Masuda M. Aortic erosion occurring in over 5 years after Amplatzer septal Occluder implantation for secundum atrial septal defect: a case report. J Cardiothorac Surg. 2019;14(1):159. PMID: 31492164; PMCID: PMC6728993. https://doi.org/10.1186/s13019-019-0982-z</mixed-citation></ref><ref id="ref42"><mixed-citation publication-type="other" xml:lang="en">Dardas P.S., Ninios V.N., Mezilis N.E., Tsikaderis D.D., Thanopoulos V.D. Percutaneous closure of atrial septal defects: immediate and mid-term results. Hellenic J Cardiol. 2010;51(2):104-12. PMID: 20378511.</mixed-citation></ref><ref id="ref43"><mixed-citation publication-type="other" xml:lang="en">El-Said H.G., Moore J.W. Erosion by the Amplatzer septal occluder: experienced operator opinions at odds with manufacturer recommendations? Catheter Cardiovasc Interv. 2009;73(7):925-30. PMID: 19455668. https://doi.org/10.1002/ccd.21931</mixed-citation></ref><ref id="ref44"><mixed-citation publication-type="other" xml:lang="en">Roymanee S., Promphan W., Tonklang N., Wongwaitaweewong K. Comparison of the Occlutech Figulla septal occluder and Amplatzer septal occluder for atrial septal defect device closure. Pediatric Cardiology. 2015;36(5):935-41. PMID: 25633819. https://doi.org/10.1007/s00246-015-1103-y</mixed-citation></ref><ref id="ref45"><mixed-citation publication-type="other" xml:lang="en">Takaya Y., Akagi T., Nakagawa K., Nakayama R., Miki T., Toh N., Ito H. Feasibility of transcatheter closure for absent aortic rim in patients with atrial septal defect. Catheter Cardiovasc Interv. 2021;97(5):859-864. PMID: 33458916. https://doi.org/10.1002/ccd.29457</mixed-citation></ref><ref id="ref46"><mixed-citation publication-type="other" xml:lang="en">Rao P.S., Harris A.D. Recent advances in managing septal defects: atrial septal defects. F1000Res. 2017;6:2042. PMID: 29250321; PMCID: PMC5701442. https://doi.org/10.12688/f1000research.11844.1</mixed-citation></ref><ref id="ref47"><mixed-citation publication-type="other" xml:lang="en">Shrivastava S., Shrivastava S., Allu S.V.V., Schmidt P. Transcatheter Closure of Atrial Septal Defect: A Review of Currently Used Devices. Cureus. 2023;15(6):e40132. PMID: 37425612; PMCID: PMC10329454. https://doi.org/10.7759/cureus.40132</mixed-citation></ref><ref id="ref48"><mixed-citation publication-type="other" xml:lang="en">Boccalandro F., Baptista E., Muench A., Carter C., Smalling R.W. Comparison of intracardiac echocardiography versus transesophageal echocardiography guidance for percutaneous transcatheter closure of atrial septal defect. Am J Cardiol. 2004;93(4):437-40. PMID: 14969617. https://doi.org/10.1016/j.amjcard.2003.10.037</mixed-citation></ref><ref id="ref49"><mixed-citation publication-type="other" xml:lang="en">Ohno N., Chaturvedi R., Lee K.J., Benson L. Characteristics of secundum atrial septal defects not percutaneously closed. Catheter Cardiovasc Interv. 2015;85(2):234-9. PMID: 25315692. https://doi.org/10.1002/ccd.25700</mixed-citation></ref><ref id="ref50"><mixed-citation publication-type="other" xml:lang="en">Jung S.Y., Choi J.Y. Transcatheter closure of atrial septal defect: principles and available devices. J Thorac Dis. 2018;10(Suppl 24):S2909-S2922. PMID: 30305951; PMCID: PMC6174149. https://doi.org/10.21037/jtd.2018.02.19</mixed-citation></ref></ref-list></back></article>
